You must have javascript enabled to use homethermostat.org !

Sears 1f56n-585 Mechanical Thermostat

24v Heat Cool White-rodgers Emerson Oem

USD $32.95

Condition : New

Free Shipping

{{variant_type_name}} :
eBay
SKU: 1F56N-585 This site contains affiliate links for which we may be compensated Home & Garden / Home Improvement / Heating, Cooling & Air / Thermostats / Non-programmable Thermostats

Notify me when the price drops

We will email you if we find a lower price on this product!

Target price (USD) $
SEARS 1F56N-585 STANDARD MECHANICAL THERMOSTAT Heat/Cool Control - 24V Low Voltage SystemWHAT THIS IS:

Genuine Sears-branded mechanical (analog) thermostat for controlling single-stage heating and cooling systems. This is a simple, reliable, non-programmable thermostat that provides accurate temperature control without complicated electronics or digital displays.

KEY FEATURES:

Simple Mechanical Operation - No programming needed, just set and forget
Heat/Cool System Switching - Controls both heating and cooling
Fan Auto/On Control - Manual fan control included
Mercury-Free Design - Environmentally friendly snap-action contacts
Universal Compatibility - Works with most 24V HVAC systems
Durable Construction - Built to last for years
Built-in Thermometer - Bimetal thermometer shows actual room temperature

DETAILED SPECIFICATIONS:

Model Number: Sears 1F56N-585
Manufacturer: White-Rodgers / Emerson (OEM for Sears)
Type: Mechanical/Analog (Non-Programmable)
Condition: [Specify: New/Used/Refurbished]
Color: Beige/White
Mounting: Horizontal

Electrical Specifications:

  • Voltage: 24V AC (30V AC Maximum)
  • Voltage Type: Low Voltage
  • Frequency: 50/60 Hz
  • Current Rating (Heating): 0.15 to 1.2 Amps
  • Current Rating (Cooling): 0 to 1.5 Amps
  • Also Compatible With: Millivolt (750mV) systems

Control Specifications:

  • Temperature Range: 50°F to 90°F (10°C to 32°C)
  • Stages: Single Stage (1H/1C)
  • System Switch: Heat - Off - Cool
  • Fan Switch: Auto - On
  • Humidity Range: 0-90% Non-condensing

Physical Specifications:

  • Shape: Rectangular/Horizontal
  • Wall Protrusion: Only extends 1-5/8" from wall
  • Includes: Wallplate and mounting hardware
COMPATIBLE SYSTEMS:

✓ Works With:

  • Central Air Conditioners
  • Central Gas Furnaces
  • Central Oil Furnaces
  • Central Electric Furnaces
  • Heat Pumps (Single Stage, No Auxiliary Heat)
  • Electric Heat Strips
  • Space Heaters
  • Hydronic (Hot Water) Heating Systems (3-wire zone valve)
  • Millivolt Systems (gas fireplaces, wall heaters)

✗ NOT For Use With:

  • Heat Pumps requiring auxiliary/emergency heat
  • Multi-stage heating or cooling systems
  • Line voltage systems (110V/240V baseboard heaters)
  • Systems requiring programmable schedules
CROSS-REFERENCE & COMPATIBILITY:

This Sears model is manufactured by White-Rodgers/Emerson

Equivalent/Similar Models:

  • White-Rodgers 1F56N-444
  • Emerson 1F56N-444
  • White-Rodgers 1F56-444
  • White-Rodgers 1F56W-444 (mercury version - discontinued)

Replaces Hundreds of Models: This thermostat was designed as a universal mercury-free replacement for hundreds of older White-Rodgers, Emerson, Honeywell, and competitive mechanical thermostats installed over the past 50+ years. Same footprint means no wall marks and no need for cover-up wallplate.

WIRING TERMINAL INFORMATION:

Standard Terminals:

  • R or RH - 24V Power (Red wire)
  • RC - Cooling Power (if separate transformer)
  • W - Heat (White wire)
  • Y - Cooling/Compressor (Yellow wire)
  • G - Fan (Green wire)
  • B or O - Heat Pump Reversing Valve (Orange/Blue wire)

Note: Factory jumper between RH and RC terminals for single transformer systems

WHAT'S INCLUDED:
  • Sears 1F56N-585 Thermostat Body
  • Mounting Subbase
  • Wallplate
  • Mounting Screws
  • [Specify if instructions/manual are included]
CONDITION NOTES:

[IMPORTANT: Add specific condition details here]

  • Specify if new in box, used, removed from working system, etc.
  • Note any cosmetic wear, scratches, discoloration
  • Confirm all switches and temperature lever operate smoothly
  • State whether it has been tested or guaranteed working
INSTALLATION INFORMATION:

Difficulty Level: Easy (DIY-Friendly)
Estimated Time: 15-30 minutes
Tools Needed: Screwdriver only

SAFETY WARNING: ⚠️ TURN OFF POWER at circuit breaker before installation
⚠️ Do not use on circuits exceeding specified voltage
⚠️ If unsure about wiring, consult a licensed HVAC technician

Installation Tip: Take a photo of your existing thermostat wiring BEFORE disconnecting anything. This will make installation much easier!

WHY CHOOSE A MECHANICAL THERMOSTAT?

Advantages Over Digital/Programmable:

  • No batteries needed - Never worry about dead batteries
  • Simple operation - Easy for anyone to understand
  • Extremely reliable - Fewer electronic components to fail
  • No programming required - Perfect for rentals, vacation homes, or people who prefer simplicity
  • Lower cost - More affordable than digital models
  • Proven technology - Mechanical thermostats have been used reliably for 50+ years

Perfect For:

  • Rental properties
  • Vacation homes/cabins
  • Senior citizens who want simplicity
  • People who maintain constant temperature
  • Basements, garages, workshops
  • Replacement for failed digital thermostats
COMMON APPLICATIONS:
  • Single-family homes
  • Apartments and condos
  • Mobile homes
  • Commercial spaces with simple HVAC needs
  • Rental properties
  • Small businesses
  • Churches and community buildings
  • Warehouses and workshops
MANUFACTURER INFORMATION:

Brand Heritage: Sears/Kenmore thermostats were manufactured by White-Rodgers, a division of Emerson Electric. White-Rodgers has been producing quality HVAC controls since 1906 and is one of the most trusted names in the industry.

VINTAGE/COLLECTIBLE VALUE:

This is an older-style mechanical thermostat from when Sears was a major appliance retailer. While functional and reliable, it also represents a piece of American home comfort history. Perfect for those maintaining period-correct homes or who prefer vintage mechanical controls.

FREQUENTLY ASKED QUESTIONS:

Q: Will this work with my heat pump?
A: Yes, but ONLY for single-stage heat pumps WITHOUT auxiliary/emergency heat. If your system requires E or AUX heat terminals, you need a different thermostat.

Q: Can I use this with my programmable schedule?
A: No, this is a non-programmable thermostat. You manually adjust the temperature as needed.

Q: What if I have a 2-stage furnace or AC?
A: This thermostat is for single-stage systems only. Multi-stage systems require a different model.

Q: Will this fit where my old thermostat was mounted?
A: Very likely yes! White-Rodgers mechanical thermostats have used the same footprint for decades, so wall marks usually aren't a problem.

Q: Does it work with baseboard heaters?
A: No, baseboard heaters typically use line voltage (110V-240V). This thermostat is for low voltage (24V) systems only.

SHIPPING INFORMATION:

[Customize this section based on your shipping policies]

📦 Careful Packaging - Thermostats are fragile and will be packed securely
📦 Fast Shipping - Ships within [specify timeframe]
📦 Tracking Provided - Track your package every step of the way


IMPORTANT NOTES:

⚠️ Wiring Verification: Please verify your existing thermostat is 24V low voltage before ordering. If you have baseboard heaters, wall-mounted line voltage thermostats, or are unsure, this may not be the correct thermostat for your system.

⚠️ Mercury Thermostats: If you are replacing an old mercury thermostat, please dispose of it properly at a household hazardous waste facility. Visit [link removed by eBay] for proper disposal information.

⚠️ Professional Installation: While this is a straightforward DIY installation for most homeowners, electrical work should only be performed by qualified individuals. When in doubt, hire a licensed HVAC technician.

Sears 1F56N-585 Mechanical Thermostat 24V Heat Cool White-Rodgers Emerson OEM
white rodgers
See more
Price type
IN STOCK OUT STOCK